APC Replacement Battery Cartridge #30 — 12 V 5.1 Ah lead-acid battery for Back-UPS BF500
Genuine APC RBC12 V 5.1 AhFully assembledFor Back-UPS BF500
The APC Replacement Battery Cartridge #30 (RBC30) is a genuine 12 V 5.1 Ah lead-acid battery cartridge for the APC Back-UPS BF500 (BF500-GR), supplied fully assembled with every connector it needs, so a UPS whose original battery has worn out can be brought back to its rated runtime without rewiring individual blocks.
APC describes its RBCs as tested and certified for compatibility with the specific APC UPS they are listed for, with a lifetime of three to five years. In practice that means one thing for you: the cartridge number must match your UPS. APC lists RBC30 for BF500-GR. Some third-party listings also link RBC30 to other 500 VA units; APC’s own compatibility list names the BF500, so for any other model ask us first.
Before you order: Check the model on the rating label of your UPS (usually underneath or at the back) against the list above. If your model is not listed, do not assume a similar-looking cartridge fits — send us the model and we will confirm the correct RBC before you order.
What's in the Box
- 1 × APC Replacement Battery Cartridge #30 (RBC30), 12 V 5.1 Ah lead-acid, 1 interconnect cable fitted
- All required connectors
- Battery recycling guide
What It Means in Practice
- One RBC30 replaces the complete battery of the BF500.
- RBC30 comes as a cartridge with its own lead and connector, shaped for the BF500 battery compartment — this is the reason a loose 12 V block is not a drop-in substitute.
- Fit it, then let the UPS charge the new battery fully before you rely on the runtime or run a self-test.
- The used battery is still hazardous waste: pack it in the box the new one came in and recycle it as the included guide describes — never put lead-acid batteries in household waste.
What Will Not Work
- It will not fit APC UPS models that APC does not list for RBC30, even if the voltage looks the same — size, connector and cartridge layout differ between RBC numbers.
- It is not a universal battery for other brands of UPS.
- It will not give more runtime than your UPS delivered when new; for longer runtime you need a larger UPS or a model that supports external battery packs.
- It will not fix a UPS whose electronics have failed — if the UPS still reports a fault with a new battery, the unit itself needs service.
Key Features
Genuine APC cartridge
Built by APC for the listed UPS models, so physical fit, connectors and charging behaviour match what the UPS expects.
Ready to install
Supplied pre-assembled with the required connectors; no soldering or re-wiring of loose blocks.
Responsible disposal
A battery recycling guide is included so the old cartridge can be returned for recycling.
APC warranty
APC covers its replacement battery cartridges with a 2-year repair or replace warranty.
Technical Specifications
| Identification |
| Part Number |
RBC30 |
| EAN / GTIN |
0731304099864 |
| Brand |
APC by Schneider Electric |
| Range |
APC Replacement Battery Cartridges (RBC) |
| Battery |
| Product type |
Replacement battery cartridge |
| Battery type |
Lead-acid (sealed, valve-regulated) |
| Battery voltage |
12 V |
| Battery capacity |
5.1 Ah |
| Cartridges required per UPS |
1 |
| Location |
Internal battery (inside the UPS) |
| Expected lifetime |
3 to 5 years (APC) |
| Physical |
| Height |
112 mm |
| Width |
99 mm |
| Depth |
74 mm |
| Net weight |
2 kg |
| Rack mounting |
Not rack-mountable (fits inside the UPS) |
| Compatibility |
| APC-listed UPS models |
BF500-GR |
| Warranty |
| Warranty |
1-Year Warranty (Singular) |
| Manufacturer Term |
2-year repair or replace warranty per APC — claims handled through Singular |
Frequently Asked Questions
How do I know my UPS battery needs replacing?
Most APC UPS models show a replace-battery indicator, alarm or failed self-test when the battery can no longer hold its charge. APC rates RBC lifetime at three to five years; high room temperature shortens it.
Can I fit a cheaper generic battery instead?
Generic blocks may match voltage and capacity, but they arrive loose: you would have to transfer connectors and brackets yourself. RBC30 arrives as a complete APC cartridge that matches the listed UPS models.
How much runtime will I get?
Runtime depends on your UPS model and the load connected to it, so APC does not publish a runtime for the cartridge itself. A new genuine RBC restores the runtime your UPS model is specified for.
Does RBC30 fit the Back-UPS ES 500?
APC’s compatibility list for RBC30 names the Back-UPS BF500. If you have a Back-UPS ES 500 or another 500 VA model, send us its model number and we will confirm the right cartridge.
Singular Expert Insight · Buyer's Guide
RBC30 is a low-capacity 12 V 5.1 Ah cartridge built for the compact Back-UPS BF500. The capacity is lower than most RBCs, which is normal for a 500 VA desktop UPS. Browse all
UPS replacement batteries if you need a different cartridge number.
✓ Buy it if you own a Back-UPS BF500 whose battery no longer holds a charge.
✕ Skip it if your UPS is any other model — confirm the cartridge number with us first.
→ Also consider APCRBC106 (12 V 6 Ah) for the Back-UPS ES 400; APCRBC110 (12 V 7 Ah) for BX500MI and BE650G2.
Not sure which cartridge your UPS takes? Send us the UPS model from its rating label and we will confirm the correct RBC before you order.