OPTICON SENSORS CRD-1006 (13167)
Please sign in so that we can notify you about a reply
OPTICON SENSORS 13167 OPTICON SENSORS CRD-1006 (13167)
Opticon CRD1006 is equipped with charging & communication features for the OPH1003 / OPH1004 / OPH1005. Two slots provide charging of both the docked terminal and a spare battery. The external communication is supported by either RS232 or USB interface.Electrical specifications
- Voltage requirement: 6 V DC output for terminal charging, 4.2 DC output for battery charging.
- Battery charging time: max. 2.5 hours.
Communication specifications
- Available interfaces: RS232, USB VCP serial port.
- Transmission speed: baud rate: 2.4 - 115.2kbps.
- Transmission mode: half duplex RS232.
Environmental specifications
Temperature during charging: -10 to 45 °C / 14 to 113 °F.
Physical specifications
- Dimensions: 68 x 96 x 70mm / 2.68 x 3.78 x 2.76in.
- Case material: ABS.
- Weight body: ca. 110g / 3.9oz.
Regulatory
- Product compliance: CE, FCC, VCCI, RoHS.
Feature list
Charger type: | Indoor |
Charger compatibility: | Bar code reader |
Power source type: | AC |
USB 2.0 ports quantity: | 1 |
Charging time: | 120 min |
Compatible products: | OPH-1003, OPH-1004, OPH-1005 |
Connectivity technology: | Contact |
Certification: | CE, FCC, VCCI, RoHS |
Colour of product: | Black |
Input voltage: | 100 - 240 V |
Output voltage: | 6 V |
Input frequency: | 50 - 60 Hz |
Output current: | 2000 mA |
Charging connector: | Y |
Operating temperature T-T: | -10 - 45 °C |
Width: | 68 mm |
Depth: | 96 mm |
Height: | 70 mm |
Weight: | 110 g |
Cables included: | RS-232, USB |
Features - OPTICON SENSORS - 13167
More Details
Product Code
V400295
EAN Code
4031574131674
Manufacturer
OPTICON SENSORS