Digitus Fiber Optic Patch Cord OS2 LC/UPC to LC/UPC Duplex Singlemode 9/125 G.657.A2 LSZH 5m Yellow
Brand:
Digitus
Digitus Fiber Optic Patch Cord OS2 LC/UPC to LC/UPC Duplex Singlemode 9/125 G.657.A2 LSZH 5m Yellow
€7.96 inc. VAT
DK-2933-05
Delivery
Order Today...
Ships...
Delivery...
ℹ️ Large or fragile items (e.g. monitors) may require extra handling time. We'll keep you informed.
Payment options
Trusted Tech Choice
Buying Benefits
Verified
Competitive EU pricing
Delivered to Cyprus from EU stock
Local warranty support
Please sign in so that we can notify you about a reply
Digitus OS2 LC to LC Duplex Fibre Patch Cord — 5 m
OS2 singlemodeLC/UPC to LC/UPC5 m · YellowLSZH · Ø 2.0 mm
The Digitus DK-2933-05 is a 5 m duplex OS2 singlemode fibre patch cord with LC on one end and LC on the other, for connecting singlemode LR/LX/BiDi transceivers, switches, media converters and patch panels. OS2 singlemode (9/125 µm) is the fibre for long-reach optics at 1310/1550 nm — LR, LX, ER and BiDi transceivers, building backbones, FTTH and carrier hand-offs.
Both ends: LC — the small latching connector used by SFP, SFP+ and SFP28 transceivers and most modern patch panels.
What's in the Box
- 1 × DIGITUS OS2 singlemode fibre patch cord, LC to LC, duplex, 5 m
- Individual test report — the cord is single-packed in a DIGITUS polybag (per datasheet)
What It Means in Practice
- Duplex means two fibres side by side, one transmit and one receive. The cord crosses Tx to Rx for you; if a link stays dark after patching, swap the two connectors on one end — it is the most common fibre patching mistake.
- 5 m is the right length between racks in a row, or from the rack to a fibre outlet across the room. Order the shortest length that reaches without tension — excess fibre has to be coiled in the cable manager.
- The fibre is ITU-T G.657.A2 bend-insensitive, so it tolerates tight routing in cable managers much better than standard fibre — but avoid kinks and sharp edges all the same.
- LSZH jacket — low smoke, zero halogen — the expected choice for offices, server rooms and public buildings.
- Keep the dust caps on until the moment you plug in. A dirty ferrule is the number one cause of high loss; clean the end faces if the ports have been left open.
What Will Not Work
- Multimode optics (SR, SX) — they need an OM3/OM4 multimode cord; singlemode fibre does not substitute.
- Ports with SC, ST, MTP/MPO connectors — this cord terminates in LC on both ends only.
- Green APC (8° angled) ports, as found on many FTTH/GPON terminals — this cord is UPC; you need an APC cord there.
- Copper RJ45 ports — fibre needs an SFP/fibre port or a media converter on each side.
Key Features
Connectors
LC on both ends, UPC polish.
Fibre grade
OS2 singlemode, 9/125 µm, ITU-T G.657.A2.
Jacket
LSZH, 2.0 mm outer diameter, yellow — the colour code most installers expect for OS2.
Quality
Ceramic ferrules; every cord is single-packed in a Digitus polybag with its own individual test report, per the Digitus datasheet.
Technical Specifications
Frequently Asked Questions
Singular Expert Insight · Buyer's Guide
Fibre patch cords are chosen by three things: the fibre grade (it must match the optics), the connector on each end and the polish. OS2 with LC to LC is the combination this cord covers. Need the active side as well? Browse our switches with SFP ports and match the transceiver to singlemode fibre.
✓ Buy it if you need a 5 m OS2 singlemode link with LC on both ends and UPC ports.
✕ Skip it if your optics are multimode (SR/SX), your ports are APC (green), or you need a different connector on either end.
→ Also consider the same Digitus OS2 cord in other lengths, or a OS2 LC to SC cord if one end of your link is different.
Not sure which grade or connector you have? Send us the model of your switch, transceiver or panel and we will check it before you order.
Features - Digitus - DK-2933-05
Colour
yellow
Length
5m
More Details
Product Code
04:258208
EAN Code
4016032248941
Manufacturer
Digitus