Digitus OS2 LC to SC Duplex Fibre Patch Cord — 5 m
OS2 singlemodeLC/UPC to SC/UPC5 m · YellowLSZH · Ø 2.0 mm
The Digitus DK-2932-05 is a 5 m duplex OS2 singlemode fibre patch cord with LC on one end and SC on the other, for connecting singlemode LR/LX/BiDi transceivers, switches, media converters and patch panels. OS2 singlemode (9/125 µm) is the fibre for long-reach optics at 1310/1550 nm — LR, LX, ER and BiDi transceivers, building backbones, FTTH and carrier hand-offs.
Both ends: LC — the small latching connector used by SFP, SFP+ and SFP28 transceivers and most modern patch panels; and SC — the square push-pull connector common on older switches, media converters, wall outlets and distribution frames.
What's in the Box
- 1 × DIGITUS OS2 singlemode fibre patch cord, LC to SC, duplex, 5 m
- Individual test report — the cord is single-packed in a DIGITUS polybag (per datasheet)
What It Means in Practice
- Duplex means two fibres side by side, one transmit and one receive. The cord crosses Tx to Rx for you; if a link stays dark after patching, swap the two connectors on one end — it is the most common fibre patching mistake.
- 5 m is the right length between racks in a row, or from the rack to a fibre outlet across the room. Order the shortest length that reaches without tension — excess fibre has to be coiled in the cable manager.
- The fibre is ITU-T G.657.A2 bend-insensitive, so it tolerates tight routing in cable managers much better than standard fibre — but avoid kinks and sharp edges all the same.
- LSZH jacket — low smoke, zero halogen — the expected choice for offices, server rooms and public buildings.
- Keep the dust caps on until the moment you plug in. A dirty ferrule is the number one cause of high loss; clean the end faces if the ports have been left open.
What Will Not Work
- Multimode optics (SR, SX) — they need an OM3/OM4 multimode cord; singlemode fibre does not substitute.
- Ports with ST, MTP/MPO, E2000 connectors — this cord terminates in LC and SC only.
- Green APC (8° angled) ports, as found on many FTTH/GPON terminals — this cord is UPC; you need an APC cord there.
- Copper RJ45 ports — fibre needs an SFP/fibre port or a media converter on each side.
Key Features
Connectors
LC to SC, UPC polish — joins equipment and panels that use different connector types.
Fibre grade
OS2 singlemode, 9/125 µm, ITU-T G.657.A2.
Jacket
LSZH, 2.0 mm outer diameter, yellow — the colour code most installers expect for OS2.
Quality
Ceramic ferrules; every cord is single-packed in a Digitus polybag with its own individual test report, per the Digitus datasheet.
Technical Specifications
| Identification |
| Part Number |
DK-2932-05 |
| EAN / GTIN |
4016032249665 |
| Brand |
Digitus |
| Official name |
DIGITUS Fiber Optic Singlemode Patch Cord, LC / SC |
| Connectivity |
| Connector A |
LC |
| Connector B |
SC |
| Polish |
PC (UPC) per Digitus family datasheet |
| Fibres |
2 (duplex) |
| Ferrule |
Ceramic |
| Fibre |
| Mode |
Singlemode |
| Fibre grade |
OS2 |
| Core / cladding |
9/125 µm |
| Fibre standard |
ITU-T G.657.A2 |
| Insertion loss |
≤ 0.30 dB (Digitus family datasheet) |
| Return loss |
≥ 30 dB, UPC (Digitus family datasheet) |
| Physical |
| Length |
5 m |
| Length tolerance |
+100 / −0 mm (lengths up to 10 m) |
| Outer diameter |
2.0 mm |
| Jacket |
LSZH |
| Colour |
Yellow |
| Operating temperature |
−40 … +85 °C |
| Standards |
IEC 60793-2 · IEC 61754-4 (SC) · IEC 61754-20 (LC) |
| Warranty |
| Warranty |
1-Year Warranty (Singular) |
| Manufacturer Term |
The manufacturer does not publish a warranty term for this item — claims handled through Singular |
Frequently Asked Questions
Will it work with my SFP+ module?
Yes, if the module is a singlemode LR/LX/BiDi type with an LC duplex port. The fibre grade must match the optic: singlemode optics need singlemode fibre.
Can I extend it?
Yes, with a matching LC or SC coupler in a panel. Every mated pair adds some insertion loss — fine for short patching, but plan long links as a single cord or a permanent installation.
Is OS2 compatible with OS1?
Yes. Both are 9/125 µm singlemode; OS2 is the current low-water-peak grade and works with any OS1/OS2 singlemode equipment.
UPC or APC — does it matter?
Yes. This cord is UPC (flat polish), the standard for data-centre and enterprise switches. Green APC ports need an APC cord.
Singular Expert Insight · Buyer's Guide
Fibre patch cords are chosen by three things: the fibre grade (it must match the optics), the connector on each end and the polish. OS2 with LC to SC is the combination this cord covers. Need the active side as well? Browse our
switches with SFP ports and match the transceiver to singlemode fibre.
✓ Buy it if you need a 5 m OS2 singlemode link with LC on one end and SC on the other and UPC ports.
✕ Skip it if your optics are multimode (SR/SX), your ports are APC (green), or you need a different connector on either end.
→ Also consider the same LC to SC cord in 10 m (DK-2932-10), or an OS2 LC to LC cord (DK-2933-05) when both ends are SFP/LC.
Not sure which grade or connector you have? Send us the model of your switch, transceiver or panel and we will check it before you order.