DIGITUS 19-inch 1U Rack PDU with 9 IEC C13 Outlets and IEC C14 Inlet, 10A Input Fuse, for UPS Connection, Aluminium

Brand:
Digitus
DIGITUS 19" 1U Rack PDU 9x IEC C13, C14 Inlet, 10A
DIGITUS 19-inch 1U Rack PDU with 9 IEC C13 Outlets and IEC C14 Inlet, 10A Input Fuse, for UPS Connection, Aluminium
€49.03 inc. VAT
Buy
DN-95429
€41.20
€49.03 inc. VAT
Ships from EU stock: 18 item(s)
Product Code
04:415081
EAN Code
4016032483557
Manufacturer
Digitus

Quick Specs

Type
19" 1U rack PDU · for UPS
Outlets
9 × IEC C13 (max 10 A each)
Input
IEC C14 inlet · 230 V / 10 A
Protection
10 A input fuse · 2.3 kVA
Delivery

Order Today...
Ships...
Delivery...
ℹ️ Large or fragile items (e.g. monitors) may require extra handling time. We'll keep you informed.
Payment options
✓ Bank Deposit
Secure checkout with flexible payment methods
Trusted Tech Choice
Buying Benefits Verified
Competitive EU pricing
Delivered to Cyprus from EU stock
Local warranty support

DIGITUS DN-95429 — 1U Rack PDU with 9 × IEC C13 Outlets and C14 Inlet

9 × IEC C13C14 inlet10 A fuseFor UPS connection

The DIGITUS DN-95429 is a 19-inch, 1U rack PDU with nine IEC C13 outlets and an IEC C14 inlet, designed to be connected to a UPS so that one UPS output feeds up to nine servers, switches or storage devices with standard C13/C14 power cords.

A 10 A input fuse protects the strip and the connected loads from overload. The aluminium profile mounts horizontally in one rack unit with the two brackets supplied.

Before you order: No input power cord is included — the PDU has a C14 inlet, not a fixed cable. To connect it to a UPS you need a C13-to-C14 cord; to connect it to a wall socket you need a Schuko-to-C13 cord rated for 10 A. Total load is limited to 10 A (2.3 kVA) for all nine outlets.

What's in the Box

  • 1 × DIGITUS DN-95429 socket strip
  • 2 × mounting brackets
  • 1 × safety instructions

What It Means in Practice

  • Turns one C13 output on a UPS into nine C13 outlets for servers and network gear.
  • C13 is the standard inlet on most switches, servers and storage — the cords that came with them plug straight in.
  • The 10 A fuse trips before the UPS output or building circuit is overloaded.
  • 1U horizontal mounting keeps power distribution tidy at the back of the rack.

What Will Not Work

  • Schuko plugs and power adapters with wall plugs do not fit C13 outlets — use a Schuko PDU for those.
  • It will not work out of the box without an input cord; order a C13–C14 or Schuko–C13 cable too.
  • No switch and no surge protection.
  • It cannot exceed 10 A in total, even if your UPS can deliver more from one outlet.

Key Features

 
Nine IEC C13 outlets
IEC 60320 C13 sockets, max 10 A per output.
 
IEC C14 inlet
Designed for connection to a UPS; feed it with a detachable cord of the length you need.
 
10 A input fuse
Protects the PDU and connected loads against overload.
 
Aluminium 1U profile
Horizontal 19-inch installation with ABS UL-94 V-0 plastic parts.

Technical Specifications

Identification
Part Number DN-95429
EAN / GTIN 4016032483557
Brand DIGITUS
Power
Rated voltage 230–250 V AC, 50/60 Hz
Rated power 2.3 kVA
Input IEC 60320 C14 inlet, 230 V / 10 A
Outlets 9 × IEC 60320 C13, max 10 A per output
Protection 10 A input fuse
Input cord Not included
Physical
Mounting 19-inch rack, 1U, horizontal
Housing Aluminium profile, ABS UL-94 V-0 parts
Dimensions (W × H × D) 482.6 × 45 × 45 mm
Net weight 0.65 kg
Warranty
Warranty 1-Year Warranty (Singular)
Manufacturer Term Warranty term not published by DIGITUS for this model — claims handled through Singular

Frequently Asked Questions

Which cable do I need to connect it?
For a UPS: an IEC C13-to-C14 cord. For a wall socket: a Schuko-to-IEC C13 cord. Neither is included.
Can I connect 9 servers?
Physically yes, but the total must stay under 10 A (about 2.3 kVA). Add up the real draw of your devices first.
Does it have surge protection?
No. Protection is provided by the 10 A input fuse against overload only.
Singular Expert Insight · Buyer's Guide
This is the right PDU when your UPS has C13 outputs and your equipment uses C13 cords — the classic server-rack layout. Remember to add the input cord to your order. For blanking panels, shelves and cable management, see our rack accessories.
✓ Buy it if you are distributing a UPS output to rack equipment with standard IEC C13 cords.
✕ Skip it if your devices have Schuko plugs or wall adapters, or you need more than 10 A on one strip.
→ Also consider Lanberg PDU-10I-0200-IEC-BK (10 × C13 with fixed C14 cord) or DIGITUS DN-95407 for Schuko devices.
Send us your UPS model and we will tell you exactly which input cord you need before you order.

Features - Digitus - DN-95429

More Details
Product Code
04:415081
EAN Code
4016032483557
Manufacturer
Digitus
  • Recently Viewed
  • Customers Also Bought
 
Why Buy from Singular

Trusted by businesses across Cyprus

Genuine products, EU stock, and expert support for every purchase.
✓ Genuine Products
Sourced through official distribution channels, with full manufacturer warranty.
✓ EU Stock
Shipped from our EU distribution network, with real-time availability on every product.
✓ B2B Ready
VAT invoices for business deduction and credit terms for verified buyers.
Expert Support
Talk to our team for sizing, configuration or volume orders.