DIGITUS DN-95429 — 1U Rack PDU with 9 × IEC C13 Outlets and C14 Inlet
9 × IEC C13C14 inlet10 A fuseFor UPS connection
The DIGITUS DN-95429 is a 19-inch, 1U rack PDU with nine IEC C13 outlets and an IEC C14 inlet, designed to be connected to a UPS so that one UPS output feeds up to nine servers, switches or storage devices with standard C13/C14 power cords.
A 10 A input fuse protects the strip and the connected loads from overload. The aluminium profile mounts horizontally in one rack unit with the two brackets supplied.
Before you order: No input power cord is included — the PDU has a C14 inlet, not a fixed cable. To connect it to a UPS you need a C13-to-C14 cord; to connect it to a wall socket you need a Schuko-to-C13 cord rated for 10 A. Total load is limited to 10 A (2.3 kVA) for all nine outlets.
What's in the Box
- 1 × DIGITUS DN-95429 socket strip
- 2 × mounting brackets
- 1 × safety instructions
What It Means in Practice
- Turns one C13 output on a UPS into nine C13 outlets for servers and network gear.
- C13 is the standard inlet on most switches, servers and storage — the cords that came with them plug straight in.
- The 10 A fuse trips before the UPS output or building circuit is overloaded.
- 1U horizontal mounting keeps power distribution tidy at the back of the rack.
What Will Not Work
- Schuko plugs and power adapters with wall plugs do not fit C13 outlets — use a Schuko PDU for those.
- It will not work out of the box without an input cord; order a C13–C14 or Schuko–C13 cable too.
- No switch and no surge protection.
- It cannot exceed 10 A in total, even if your UPS can deliver more from one outlet.
Key Features
Nine IEC C13 outlets
IEC 60320 C13 sockets, max 10 A per output.
IEC C14 inlet
Designed for connection to a UPS; feed it with a detachable cord of the length you need.
10 A input fuse
Protects the PDU and connected loads against overload.
Aluminium 1U profile
Horizontal 19-inch installation with ABS UL-94 V-0 plastic parts.
Technical Specifications
Frequently Asked Questions
Singular Expert Insight · Buyer's Guide
This is the right PDU when your UPS has C13 outputs and your equipment uses C13 cords — the classic server-rack layout. Remember to add the input cord to your order. For blanking panels, shelves and cable management, see our rack accessories.
✓ Buy it if you are distributing a UPS output to rack equipment with standard IEC C13 cords.
✕ Skip it if your devices have Schuko plugs or wall adapters, or you need more than 10 A on one strip.
→ Also consider Lanberg PDU-10I-0200-IEC-BK (10 × C13 with fixed C14 cord) or DIGITUS DN-95407 for Schuko devices.
Send us your UPS model and we will tell you exactly which input cord you need before you order.