Equip 333319 — 1U Rack PDU with 6 × IEC C19 Outlets and C20 Input
6 × IEC C19C20 input plugOn/Off switch16 A · 3500 W
The Equip 333319 is a 19-inch, 1U rack PDU with six IEC C19 high-current outlets and an IEC C20 input plug, made for server and storage cabinets where equipment uses C19/C20 power connections — typically larger servers, blade chassis, high-wattage storage arrays and UPS-fed racks.
Because it is fed by a C20 plug rather than a wall plug, it is designed to hang off a C19 socket on a UPS or an upstream PDU, distributing that 16 A feed to up to six high-power devices in a single rack unit, with a master switch to cut power to the whole strip.
Before you order: The input is an IEC C20 plug — it does not go into a Schuko wall socket. You need a C19 outlet on a UPS or PDU to feed it. The outlets are C19, so devices with a standard C14 inlet need a C20-to-C13 cord; the 3500 W / 16 A is the total for all six outlets.
What's in the Box
- 1 × Equip 333319 6-outlet C19 rack PDU with fixed 1.8 m cable and C20 plug
- Screw kit for rack mounting
- Quick installation guide
What It Means in Practice
- Lets one 16 A C19 output on a UPS feed six high-power devices without daisy-chaining power strips.
- C19/C20 connectors are rated for higher current than C13/C14, which is why servers and storage with large power supplies use them.
- The aluminium 1U body mounts horizontally at the back or front of a 19-inch rack.
- The on/off switch powers the whole strip down at once for maintenance.
What Will Not Work
- It will not plug into a wall socket — there is no Schuko or UK plug, only an IEC C20 plug.
- Ordinary IEC C13 cords (the kind used by most switches and PCs) do not fit C19 outlets; you need C20-to-C13 or C20-to-C14 cables.
- No surge protection, metering, remote switching or per-outlet breakers are published for this unit.
- It does not add capacity: six devices together must stay within 16 A / 3500 W.
Key Features
Six IEC C19 outlets
High-current C19 sockets for servers, storage and other equipment with C20 inlets or C20-terminated cords.
IEC C20 input plug
Designed to be fed from a C19 outlet on a UPS or upstream PDU in the same cabinet.
Master on/off switch
Integrated switch to power the full strip on or off.
Aluminium 1U shell
Horizontal 19-inch installation in one rack unit with a rigid aluminium housing.
Technical Specifications
| Identification |
| Part Number |
333319 |
| EAN / GTIN |
4015867241301 |
| Brand |
Equip |
| Power |
| Input |
250 V, 50/60 Hz, 16 A |
| Maximum load |
3500 W (total, all outlets) |
| Outlets |
6 × IEC C19 |
| Input connector |
IEC C20 plug |
| Switch |
Integrated power on/off switch |
| Cable |
| Cable |
H05VV-F 3G 1.5 mm² |
| Cable length |
1.8 m |
| Physical |
| Mounting |
19-inch rack, 1U, horizontal |
| Housing |
Aluminium |
| Colour |
Silver |
| Dimensions (W × D × H) |
482.6 × 45 × 45 mm |
| Weight |
0.79 kg |
| Compliance |
CE, RoHS, REACH |
| Warranty |
| Warranty |
1-Year Warranty (Singular) |
| Manufacturer Term |
Warranty term not published by Equip for this model — claims handled through Singular |
Frequently Asked Questions
What can I plug the C20 input into?
A C19 outlet — usually on a UPS (many 3 kVA and larger rack UPS units have one) or on an upstream PDU. If you only have wall sockets, a Schuko-input PDU is the right choice instead.
Can I connect normal PCs or switches?
Yes, with a C20-to-C13 power cord for each device, as long as the total stays within 16 A.
Is this the same as a C13 PDU?
No. C19 sockets are larger and rated for higher current; C13 plugs will not fit. Check the cords on your equipment before ordering.
Singular Expert Insight · Buyer's Guide
C19 PDUs make sense when your servers or storage already use C19/C20 cords, or when a UPS with a C19 output is the single feed for the rack. If your gear uses ordinary C13 cords, a C13 PDU is cheaper and simpler. For the rest of the cabinet, browse our
rack accessories.
✓ Buy it if your rack is fed from a UPS or PDU with a C19 outlet and your servers use C19/C20 power connections.
✕ Skip it if you need to plug into a wall socket, your devices use standard C13 cords, or you need surge protection.
→ Also consider Equip 333309 with seven Schuko outlets, surge protection and a wall plug, or a C13-outlet PDU such as Lanberg PDU-10I-0200-IEC-BK.
Send us your UPS model and the power cords your servers use, and we will confirm whether a C19 PDU is the right fit before you order.