Rittal DK 7200.210 — Schuko to IEC C13 Power Cable, 1.8 m, for CMC III
Schuko → C131.8 m1 mm² · 3-pole230 V
The Rittal DK 7200.210 is a 1.8 m power connection cable with a Schuko earthing-pin plug (CEE 7/4, type F) on one end and an IEC C13 socket on the other. Rittal supplies it for the CMC III power pack and CMC III Power Unit, and it powers any device with a standard C14 inlet from a European wall socket.
The cable is three-pole with 1 mm² conductors in a PVC sheath and is rated 230 V. Rittal’s photo shows an angled Schuko plug, which sits flatter against a wall socket or a power strip than a straight plug.
Use it where a CMC III monitoring unit, a switch or a small device in a cabinet needs to be fed from a wall socket or a Schuko power strip rather than from a C13 rack PDU.
Before you order: The plug is Schuko (CEE 7/4, type F) for continental European sockets. Cyprus wall sockets are UK type G (BS 1363), so in Cyprus it needs a Schuko power strip or PDU — or choose a lead with a UK plug.
What's in the Box
- 1 × Rittal DK 7200.210 power connection cable, Schuko to IEC C13, 1.8 m
- Packaging unit: 1 piece
What It Means in Practice
- Typical use: powering a Rittal CMC III power pack or Power Unit from a Schuko socket strip in the cabinet.
- It also powers any IEC C14-inlet device — switches, monitors, small servers — from a Schuko outlet.
- 1.8 m reaches from a socket strip at the base of a cabinet to devices in the lower and middle rack units.
- Route the cable along the rear vertical profile and secure it with a tie so it does not pull on the C13 end.
What Will Not Work
- It does not plug directly into a UK/Cyprus type G wall socket without a Schuko power strip.
- It does not connect to rack PDU outlets (C13) — for PDU-to-device links use the C14–C13 Rittal DK 7200.215.
- It does not fit C19/C20 inlets on large UPS units or high-power servers.
- It is not a surge protector — it is a plain power cable.
Key Features
Schuko to IEC C13
Continental European earthing-pin plug to the standard C13 socket found on almost every IT power cord.
Angled Schuko plug
The plug shown by Rittal is angled, so it sits flatter in socket strips.
1.8 m, 1 mm²
Three-core 1 mm² cable in PVC, 1.8 m long.
Rittal CMC III accessory
Listed by Rittal for the CMC III power pack and CMC III Power Unit.
Technical Specifications
| Identification |
| Part Number |
DK 7200.210 (7200210) |
| EAN / GTIN |
4028177164314 |
| Brand |
Rittal |
| Official Name |
Connection cable for power packs — connection cable, for CMC III |
| Electrical |
| Plug |
Earthing-pin plug CEE 7/4 (type F) |
| Socket |
IEC 60320 C13 |
| Rated Voltage |
230 V AC |
| Poles / Cross-section |
3-pole, 1 mm² |
| Physical |
| Length |
1.8 m |
| Cable Material |
PVC |
| Weight |
0.21 kg |
| Packaging Unit |
1 piece |
| Warranty |
| Warranty |
1-Year Warranty (Singular) |
| Manufacturer Term |
Manufacturer warranty per Rittal terms (term not published for this part) — claims handled through Singular |
Frequently Asked Questions
Can I plug it into a wall socket in Cyprus?
Not directly. Cyprus uses UK type G sockets; this cable has a Schuko plug, so use it with a Schuko power strip or PDU.
What is the difference from the Rittal 7200.215?
The 7200.215 has a C14 plug instead of a Schuko plug, so it connects to a PDU or UPS outlet rather than to a wall socket or Schuko strip.
Does it work with non-Rittal devices?
Yes, the C13 socket fits any device with a standard IEC C14 inlet.
Is it long enough for a 42U cabinet?
At 1.8 m it reaches from a socket strip at the bottom of the cabinet to the lower and middle rack units; for the top of a 42U cabinet plan the strip position accordingly.
Singular Expert Insight · Buyer's Guide
Plug standards decide whether a power cable works on installation day. This Rittal lead is the right choice when a CMC III unit or other IEC device has to be fed from a Schuko strip; for links from a C13 rack PDU, the 7200.215 is the correct part. Browse our
rack accessories for PDUs, shelves and cable management.
✓ Buy it if you need a 1.8 m Schuko-to-C13 lead for a CMC III power pack or any IEC device fed from a Schuko strip.
✕ Skip it if you need a UK type G plug, or a PDU-to-device lead (take 7200.215).
→ Also consider Rittal DK 7200.215 (C14 to C13 extension, 1.8 m).
Tell us where the cable will plug in and which device it powers, and we will confirm the right lead before you order.