Datalogic Gryphon GM4500-HC | 2D Imager Cordless Healthcare Scanner | STAR 433 MHz RF | (RF Kit — Scanner + Cradle + Cable Incl.)
The Datalogic Gryphon GM4500-HC is a cordless 2D area imager engineered specifically for healthcare environments where hygiene, durability, and reliable scanning are non-negotiable. Featuring Datalogic's STAR 433 MHz RF cordless system and contact-free inductive wireless charging, it delivers 50-metre scanning freedom without the contamination risks associated with physical charging contacts. The GM4500-HC-433K1 kit includes the scanner, the WLC4090-HC-433 inductive charging base, and a USB cable — everything needed for immediate deployment in clinical, pharmacy, and laboratory settings.
Healthcare-Grade Design & Antimicrobial Housing
The GM4500-HC is built from the ground up for sterile environments. Its enclosure is treated with antimicrobial additives that actively inhibit bacterial growth on contact surfaces — a critical feature in hospitals, pharmacies, and labs where cross-contamination is a constant concern. The disinfectant-ready housing withstands daily cleaning with harsh chemical agents including alcohol and bleach-based solutions without surface degradation. The white colour scheme is standard for healthcare device tracking and visual hygiene protocols, and the smooth, contact-minimising body design reduces hard-to-clean crevices.
STAR 433 MHz RF Cordless System
The GM4500-HC-433K1 uses Datalogic's proprietary STAR (Simultaneously Transmitting And Receiving) 433 MHz cordless system, which provides a wireless range of up to 50 metres in open environments. The STAR system supports point-to-point and point-to-multipoint configurations, allowing a single base station to serve multiple scanners in a network. The 433 MHz frequency offers strong penetration through walls and shelving common in clinical settings, reducing dead spots compared to higher-frequency RF systems. The WLC4090-HC-433 base connects to the host via USB, keeping the host-side setup simple and driver-compatible with standard HID profiles.
2D Megapixel Imaging Performance
At the core of the GM4500-HC is a 2D megapixel area imager with white illumination and a 4-dot aiming pattern with a centre cross for precise targeting. It reads all major 1D, 2D, postal, stacked, and composite code symbologies, plus Digimarc and DotCode — essential for pharmaceutical serialisation and unit-dose medication scanning. The omnidirectional read capability means no orientation adjustment is needed, delivering consistent throughput at 35 images per second. Digital watermarking support allows reading of Digimarc-encoded packaging without visible barcodes, future-proofing the scanner for evolving pharmaceutical labelling standards.
Inductive Wireless Charging System
The GM4500-HC charges inductively through the WLC4090-HC-433 base — there are no exposed metal charging contacts on the scanner or cradle. This design eliminates a common contamination and corrosion point in healthcare scanners: physical contacts accumulate biofilm and corrode with frequent chemical exposure. The scanner simply rests in the cradle and begins charging automatically with no alignment pins or mechanical connectors. Scan-while-charging capability means workflows are never interrupted during top-up charges between patient interactions. The user-replaceable Li-Ion 3250 mAh battery ensures scanners can be swapped rather than waiting for a full charge cycle during peak operational hours.
Durability & Environmental Resistance
The GM4500-HC carries an IP52 rating, providing protection against dust ingress and low-pressure water spray — appropriate for the splash and cleaning environments typical of healthcare facilities. It withstands repeated drops from 1.8 metres (6 feet) to concrete, covering standard countertop and nurse station working heights. The operating temperature range of 0°C to 50°C covers both refrigerated medication storage rooms and warm clinical areas. A 3-year warranty from Datalogic reflects confidence in the device's long-term reliability under the demanding conditions of 24/7 healthcare operations.
| Specification | Detail |
|---|---|
| Imager Type | 2D Megapixel Area Imager, Omnidirectional |
| Aiming System | 4-dot pattern with centre cross |
| Scan Speed | 35 IPS |
| Symbologies | 1D, 2D, Postal, Stacked, Digimarc, DotCode, Composite |
| Wireless System | Datalogic STAR 433 MHz RF |
| Wireless Range | Up to 50 m (line-of-sight) |
| Battery | Li-Ion 3250 mAh, user-replaceable |
| Charging | Inductive wireless (no contacts), scan-while-charging |
| IP Rating | IP52 |
| Drop Resistance | 1.8 m / 6 ft |
| Dimensions (L×W×H) | 166 × 109 × 68 mm |
| Weight | 235 g |
| Operating Temperature | 0°C to 50°C |
| Colour | White (healthcare) |
| Healthcare Features | Antimicrobial housing, disinfectant-ready, inductive charging |
| Warranty | 3 years |
| Kit Contents | Scanner + WLC4090-HC-433 Inductive Cradle + USB Cable |
Frequently Asked Questions
What is included in the GM4500-HC-433K1 kit?
The K1 kit includes the GM4500-HC scanner, the WLC4090-HC-433 inductive wireless charging base (cradle), and a USB cable to connect the base to the host system. No additional accessories are required for out-of-the-box operation.
How does inductive charging work and why does it matter in healthcare?
Inductive charging uses electromagnetic fields to transfer power through the cradle surface without any metal contacts. In healthcare environments, exposed contacts harbour biofilm and corrode rapidly with chemical disinfectant use. Contact-free charging eliminates this failure point entirely, extending cradle and scanner lifespan while maintaining hygiene standards.
What is the wireless range of the STAR 433 MHz system?
The Datalogic STAR 433 MHz system provides a range of up to 50 metres line-of-sight from the WLC4090-HC-433 base. The 433 MHz frequency penetrates walls and shelving more effectively than 900 MHz or 2.4 GHz systems, making it well suited to clinical ward environments with partitioned spaces.
Is the GM4500-HC compatible with standard (non-HC) Datalogic GM4500 cradles?
No — the GM4500-HC uses inductive charging and requires the WLC4090-HC-433 base specifically. Standard GM4500 cradles use physical contacts and are not compatible. Always use HC-designated accessories to maintain both charging functionality and healthcare compliance.