DIGITUS DN-95427 — 19" 1U PDU with 8 x C13 and 2 x C19 outlets and C20 input for UPS connection
8 x C13 + 2 x C19IEC C20 input16 A · 3.6 kVAPull-out protection
The DIGITUS DN-95427 is a 19-inch, 1U rack PDU with eight IEC C13 and two IEC C19 outlets, fed through a 2 m cable with an IEC C20 plug and rated 16 A / 3.6 kVA. DIGITUS designs it to be connected to a UPS: one C19 output of the UPS feeds the whole rack.
Every outlet has pull-out (extraction) protection, so C13 and C19 cords stay seated when the rack is serviced. The two C19 outlets take high-power devices such as larger servers or blade chassis; the C13 outlets cover switches, firewalls and storage.
Before you order: The input is an IEC C20 plug: it needs a C19 outlet on a UPS or upstream PDU, not a wall socket. Your devices need C14-to-C13 cords (or C20-to-C19 for the two high-power outlets). DIGITUS lists the outlets as having pull-out protection; standard IEC cords fit.
What's in the Box
- 1 x DIGITUS DN-95427 19" PDU with fixed 2 m supply cable (IEC C20 plug)
- 2 x 19" mounting brackets
- 1 x safety instructions
- No device power cords included
What It Means in Practice
- Plug the C20 into the UPS C19 outlet and all ten rack outlets run on UPS power — the standard layout for a protected server rack.
- Two C19 outlets mean high-draw equipment does not need an adapter or a second PDU.
- Pull-out protection keeps cords from working loose when you move cables behind the rack.
- The 16 A / 3.6 kVA limit is for the whole PDU and must also fit within the UPS output rating.
What Will Not Work
- Plugging into a wall socket — the C20 plug needs a C19 outlet on a UPS or PDU.
- Device cords with Schuko or BS 1363 plugs — use C14-to-C13 or C20-to-C19 cords.
- UPS units without a C19 outlet — most small UPS models only have C13 or Schuko outlets.
- Surge protection, fuse or on/off switch — none on this model.
Key Features
C20 input for UPS
2 m cable with IEC C20 plug for a UPS C19 output.
8 x C13 + 2 x C19
Ten IEC outlets in 1U, including two high-power C19.
Pull-out protection
Each outlet holds its C13 or C19 cord in place.
Aluminium profile
Rigid housing, ABS UL-94 V-0 plastic parts.
Technical Specifications
Frequently Asked Questions
Singular Expert Insight · Buyer's Guide
This is the PDU to pair with a rack UPS that has a C19 output: one cable from the UPS, ten locked IEC outlets in the rack. If your UPS only has C13 outlets, it cannot feed it. More rack power and mounting parts are in our rack accessories.
✓ Buy it if you feed the rack from a UPS with a C19 outlet and use IEC-corded equipment.
✕ Skip it if your UPS has no C19 outlet or the rack is fed straight from a wall socket.
→ Also consider DIGITUS DN-95426 (12 x C13 with CEE 7/7 plug) or DN-95410-IT (C14 input, 8 x Italian sockets).
Not sure your UPS has a C19 outlet? Send us the UPS model and we will check before you order.