LINDY 3m IEC C14 to C15 Power Extension Cable · Hot-Condition C15 · 10A 250V · H05VV-F 3G 1.0mm² · Black

Μάρκα:
Lindy
LINDY 3m IEC C14 to C15 Power Extension Cable
LINDY 3m IEC C14 to C15 Power Extension Cable · Hot-Condition C15 · 10A 250V · H05VV-F 3G 1.0mm² · Black
€14.21 inc. VAT
30402
€11.94
€14.21 με Φ.Π.Α.
Διαθέσιμο με παραγγελία: 3 Είδη
Product Code
CS51125
EAN Code
4002888304023
Manufacturer
Lindy

Quick Specs

Type
IEC power extension cable
Connectors
C14 male to C15 female (hot condition)
Key spec
10A / 250V AC · 120 °C
Compatibility
C14 or C16 appliance inlets
Delivery

Order Today...
Ships...
Delivery...
ℹ️ Large or fragile items (e.g. monitors) may require extra handling time. We'll keep you informed.
Payment options
✓ Bank Deposit
Secure checkout with flexible payment methods
Trusted Tech Choice
Buying Benefits Verified
Competitive EU pricing
Delivered to Cyprus from EU stock
Local warranty support

LINDY 3m IEC C14 to C15 Power Extension Cable

C14 → C1510A / 250V120 °C hot condition3 m

The LINDY 30402 is a 3 metre IEC C14 to C15 mains extension cable with H05VV-F 3G 1.0mm² copper conductors, rated 10A at 250V AC, used to connect equipment with a C16 or C14 inlet to a PDU, UPS or other C13-style outlet.

The C15 end is the "hot condition" version of the familiar kettle-style connector: it has a notch that lets it mate with C16 inlets on equipment that runs hot, and LINDY rates it for temperatures up to 120 °C. That makes it the correct cable for broadcast gear, network equipment in hot racks, and any device whose manual asks for a C15 lead — and it still plugs into normal C14 inlets.

Before you order: Check the inlet on your device. This cable ends in a C14 plug, so it needs a C13 or C15 socket such as a rack PDU or UPS outlet — it does not plug into a wall socket.

What's in the Box

  • 1 × LINDY 3m IEC C14 to IEC C15 power extension cable, black (30402)

What It Means in Practice

  • Use it between a rack PDU or UPS (C13 outlets) and a switch, server or AV device that has a C16 or C14 inlet.
  • The C15 connector is the correct choice when a device specifies a hot-condition lead, where a standard C13 cable is not permitted.
  • 1.0mm² copper conductors support the full 10A rating of the connectors.
  • 3 m gives enough slack to route power between neighbouring racks or from a floor-standing UPS to a desk or cabinet.

What Will Not Work

  • No wall plug: the C14 end fits only C13/C15 sockets such as PDUs, UPS outlets and power strips with IEC outlets.
  • Not for C19/C20 16A equipment such as high-power servers and large UPS units; those need C19/C20 cables.
  • A C15 connector will not fit a standard C13 appliance inlet in reverse — check you need C14/C16 at the device.
  • The 10A limit applies; do not use it to feed a power strip that supplies more than 10A in total.

Key Features

 
Hot-condition C15
Rated to 120 °C for devices with C16 inlets or high inlet temperatures.
 
10A / 250V AC
Full rating of the IEC C14/C15 connector system.
 
H05VV-F 3G 1.0mm²
Three copper conductors in a 6.8 mm PVC jacket.
 
10-year warranty
LINDY backs this cable with a 10-year manufacturer warranty.

Technical Specifications

Identification
Part Number 30402
EAN / GTIN 4002888304023
Brand LINDY
Product 3m IEC C14 to IEC C15 mains extension cable
Connectors
Connector A IEC C14 male (plug), brass pins, nickel plated
Connector B IEC C15 female, hot condition, phosphor bronze contacts, nickel plated
Cable
Length 3 m
Cable type H05VV-F 3G 1.0mm²
Conductor Copper, 3 × 1.0mm²
Jacket PVC, 6.8 mm diameter
Colour Black
Electrical
Rating 10A / 250V AC
Heat resistance (C15) Up to 120 °C
Operating temperature -10 °C to 60 °C
Storage temperature -20 °C to 70 °C
Compliance
Certifications CE, RoHS, REACH
Warranty
Warranty 1-Year Warranty (Singular)
Manufacturer Term 10-year limited warranty per LINDY — claims handled through Singular

Frequently Asked Questions

What is the difference between C13 and C15?
A C15 connector has a notch that fits C16 inlets used on equipment that runs hot, and it is rated to 120 °C. A standard C13 connector does not fit C16 inlets and is rated for lower temperatures.
Will the C15 end fit a normal PC or monitor inlet?
Yes. A C15 fits standard C14 inlets as well as C16 inlets, so you can use it on ordinary IT equipment too.
Can I plug this into a wall socket?
No. The other end is a C14 plug, which only fits C13 or C15 outlets such as those on a PDU or UPS.
Singular Expert Insight · Buyer's Guide
IEC extension cables are what you use inside a rack: they run from the PDU or UPS to each device without wall plugs taking up space. Choose C15 when any of your equipment has a C16 inlet or runs hot; it works with standard C14 inlets as well. For PDUs, shelves and cable managers, see our rack accessories.
✓ Buy it if you need to power a C14 or C16 device from a PDU or UPS and want the hot-condition rating.
✕ Skip it if your device has a C20 inlet or draws more than 10A, or you need a lead with a wall plug.
→ Also consider Shorter or longer LINDY C14–C15 extensions in the same series for tidy rack cabling.
Not sure which IEC connector your device uses? Send us the model or a photo of the inlet and we will confirm the right cable.

Colour
black
Length
3m
Χαρακτηριστικά
Product Code
CS51125
EAN Code
4002888304023
Manufacturer
Lindy
  • Recently Viewed
  • Bestsellers
 
Γιατί να αγοράσετε από τη Singular

Εμπιστοσύνη επιχειρήσεων σε όλη την Κύπρο

Αυθεντικά προϊόντα, απόθεμα ΕΕ και τεχνική υποστήριξη σε κάθε αγορά.
✓ Αυθεντικά Προϊόντα
Προμήθεια από επίσημα κανάλια διανομής, με εργοστασιακή εγγύηση.
✓ Απόθεμα ΕΕ
Αποστολή από το δίκτυο διανομής μας στην ΕΕ, με διαθεσιμότητα σε πραγματικό χρόνο σε κάθε προϊόν.
✓ Έτοιμοι για B2B
Τιμολόγια με ΦΠΑ για έκπτωση δαπανών και όροι πίστωσης για εγκεκριμένους πελάτες.
Τεχνική Υποστήριξη
Μιλήστε με την ομάδα μας για επιλογή, παραμετροποίηση ή παραγγελίες όγκου.