Rittal DK 7200.215 — IEC C14 to C13 Extension Cable, 1.8 m, for CMC III
C14 → C131.8 m1 mm² · 3-pole230 V
The Rittal DK 7200.215 is a 1.8 m IEC extension cable with a C14 plug on one end and a C13 socket on the other, made by Rittal for its CMC III monitoring power packs and equally at home as a power jumper inside a 19" rack. It uses 3 × 1 mm² conductors in a PVC sheath and is rated 230 V (110 V DC).
Inside a rack, C14-to-C13 leads are the standard way to connect a device’s IEC inlet to a PDU or UPS outlet. Rittal lists this part as the extension cable for the CMC III system, so it is the correct lead when a CMC III power pack has to reach an IEC outlet further away.
The C14 end is a plug, not a wall plug: it goes into a C13-style outlet such as a rack PDU or UPS. It cannot be plugged into a Schuko wall socket.
Before you order: The C14 end fits C13 outlets on PDUs and UPS units, not wall sockets. For a Schuko wall socket you need the Rittal DK 7200.210 instead.
What's in the Box
- 1 × Rittal DK 7200.215 IEC C14–C13 extension cable, 1.8 m
- Packaging unit: 1 piece
What It Means in Practice
- Typical use: from a rack PDU (C13 outlet) to a CMC III power pack or any device with a C14 inlet.
- 1.8 m reaches from a vertical PDU at the back of a 42U cabinet to most devices in the same rack.
- It also extends an existing C13 power cord where the original lead is too short.
- Keep spare length coiled loosely and away from the air intake of servers and switches.
What Will Not Work
- It does not plug into a wall socket (Schuko / type F) — use the 7200.210 for that.
- It does not fit C19/C20 inlets used by large UPS units and high-power servers.
- It is not a surge protector or PDU — it is a plain cable.
- Rittal does not publish a rated current for this part, so do not use it for loads above what a standard 1 mm² C13 lead is intended for.
Key Features
IEC C14 to C13
Standard rack power connectors: the C14 plug goes into a PDU/UPS outlet, the C13 socket into the device.
1.8 m length
Long enough to cross a rack from a vertical PDU to equipment on the front rails.
1 mm² three-core
Three-pole cable with 1 mm² conductors in a PVC sheath.
Made for CMC III
Listed by Rittal as the extension cable for its CMC III monitoring power packs.
Technical Specifications
| Identification |
| Part Number |
DK 7200.215 (7200215) |
| EAN / GTIN |
4028177305519 |
| Brand |
Rittal |
| Official Name |
Connection cable for power packs — extension cable, C13/C14, for CMC III |
| Electrical |
| Connector 1 |
IEC 60320 C14 (plug) |
| Connector 2 |
IEC 60320 C13 (socket) |
| Rated Voltage |
230 V AC; 110 V DC |
| Poles / Cross-section |
3-pole, 1 mm² |
| Physical |
| Length |
1.8 m |
| Cable Material |
PVC |
| Weight |
0.168 kg |
| Packaging Unit |
1 piece |
| Warranty |
| Warranty |
1-Year Warranty (Singular) |
| Manufacturer Term |
Manufacturer warranty per Rittal terms (term not published for this part) — claims handled through Singular |
Frequently Asked Questions
What is the difference from the Rittal 7200.210?
The 7200.210 has a Schuko (CEE 7/4, type F) wall plug and a C13 socket — it connects to a wall socket. The 7200.215 has a C14 plug — it connects to a PDU or UPS outlet.
Can I use it with non-Rittal equipment?
Yes, C13/C14 are standard IEC connectors used by switches, servers, monitors and PDUs.
Is it suitable for a UPS output?
Yes, if the UPS has C13 outlets. It does not fit C19 outlets.
Does it include a locking clip?
Rittal does not list a locking mechanism, so treat it as a standard push-fit IEC lead.
Singular Expert Insight · Buyer's Guide
In racks, the wrong plug type is the most common reason a power lead does not fit on the day of installation. Count your PDU outlets and device inlets first: C14-to-C13 like this one is for PDU-to-device links, while Schuko-to-C13 is for wall sockets. Browse our
rack accessories for PDUs, shelves and cable management.
✓ Buy it if you need a 1.8 m C14–C13 lead from a PDU or UPS to a CMC III power pack or any IEC device.
✕ Skip it if you need to plug into a wall socket (take 7200.210) or into a C19 outlet.
→ Also consider Rittal DK 7200.210 (Schuko to C13, 1.8 m).
Tell us your PDU and device models and we will confirm the right power lead before you order.